ARCHETYPE B: OEM COMPATIBILITY MATRIX

Taco 007-F5 Drop-in Cross-Reference Guide

Engineering comparison across physical flange standards, flow curves, power draw, and mechanical interchangeability for the most common residential heating circulator in North America.

Spec Alignment: OEM vs Drop-in Competitors

Parameter Taco 007-F5 (Benchmark OEM) Grundfos UPS15-58FC Bell & Gossett NRF-22 Taco 007e ECM (Modern Upgrade) Interchange Verdict
Flange-to-Flange 6-3/8" (162 mm) 6-3/8" (162 mm) 6-3/8" (162 mm) 6-3/8" (162 mm) 100% Match
Bolt Spacing (BCD) 3-3/16" (81 mm) 3-3/16" (81 mm) 3-3/16" (81 mm) 3-3/16" (81 mm) 100% Match
Flange Bolt Holes 2 × 1/2" slots (7/16" bolts) 2 × 1/2" slots 2 × 1/2" slots 2 × 1/2" slots 100% Match
Shutoff Head (Max ft) 10.0 ft 19.0 ft (Spd 3) / 14 ft (Spd 2) 15.0 ft 10.0 ft Drop-in Valid
Max Flow (GPM @ 0 ft) 23.0 GPM 17.0 GPM 22.0 GPM 16.0 GPM Drop-in Valid
Electrical Input 115V / 60Hz / 0.71A 115V / 60Hz / 0.75A 115V / 60Hz / 0.80A 115V / 60Hz / 0.54A 100% Match
Operating Wattage 85 Watts (Fixed) 60W / 75W / 87W (3-Speed) 92 Watts (Fixed) 5W – 44W (Modulating) 85% Energy Drop
Direct Action View Taco 007 View Grundfos View B&G View 007e ECM —

Critical Fit Dimensions Checklist

PHYSICAL GEOMETRY

Flange Dimensions

Flange-to-Flange Overall6-3/8" (162 mm)
Flange Width (Ear-to-Ear)4-1/4" (108 mm)
Bolt Hole Center-to-Center3-3/16" (81 mm)
Flange Bolt Size7/16" x 1-1/2" Grade 5 Hex
Companion Flange Pipe Sizes3/4", 1", 1-1/4" NPT / Sweat
MOTOR & ELECTRICAL

Electrical Clearance

Line Voltage115V AC ±10%, 60 Hz, 1-Phase
Conduit Knockouts1/2" Standard Trade (7/8" Hole)
Terminal Box OrientationRotatable 90° / 180° (4 Allen bolts)
Motor Clearance Outward5-1/8" (130 mm) from pipe center
Fluid Temperature Limits40°F (4°C) to 230°F (110°C)
Known Mechanical & Installation Gotchas